Technical data:
Motor type | Power, kW | Voltage, V | Synchronous rotation speed, rpm | Design dynamic moment of armature inertia, kgm2 | Weight, kg |
АТ20С8-12УХЛ4 | 3550 | 6000 | 500 | 7500 | 34600 |
АТ20С8- 12Т3 | 3150 |
Motor type | Power, kW | Voltage, V | Synchronous rotation speed, rpm | Design dynamic moment of armature inertia, kgm2 | Weight, kg |
АТ20С12-12УХЛ4 | 4000 | 10000 | 500 | 10750 | 44200 |
АТ20С12- 12Т3 | 3550 | 11000 |